1791
Our 1791 reticulated polyurethane foam has a density of 1.4 PCF / 22.4 kg/m³. This material has a regular cell structure, with a 15 PPI count. This material meets fired retardant classification; UL900, Class 2. It has a Volumetric air flow rate 24 ± 4 cfm. The foam has a tensile strength Dry Heat Loss of 15% max.
Product Description
Our 1791 reticulated polyurethane foam has a density of 1.4 PCF / 22.4 kg/m³. This material has a regular cell structure, with a 15 PPI count. This material meets fired retardant classification; UL900, Class 2. It has a Volumetric air flow rate 24 ± 4 cfm. The foam has a tensile strength Dry Heat Loss of 15% max.
Measurements
Shore Hardness | |
---|---|
Density | 1.2 - 1.6PCF (lb/ft³) 19.2 - 25.6Kg/m³ |
Compression | 0.5 - 0.5psi 3.4 - 3.4kPA |
Service Temperature |
Technical Data
Item | Specs | Test Method |
Grade | ||
Density (PCF) (kg/m3) | 1.2 – 1.6 PCF 19.2 – 25.6 kg/m3 | ASTM D 3574-95 |
Compression Deflection (CFD)(psi)(kPa) @40% | 0.5 psi 3.4 kPa | ASTM D 3574-95 |
Shore Hardness OO (Durometer) | ||
Compression Set (%) @50% | 15 max | ASTM D 3574-95 |
Tensile Strength (psi)(kPa) | 18 psi min 124 kPa | ASTM D 3574-95 |
Elongation (%) | 180 | ASTM D 3574-95 |
Tear Strength Resistance (ppi)(lb/in) | 5 | ASTM D 3574-95 |
Water Absorption by Weight % | ||
Accelerated Age Testing | ||
Service Temperature (°C)(°F) – Low – High Continuous – High intermittent | ASTM D 3574-95 | |
Flame Resistance | UL900, Class 2, Non Fire Retardant | ASTM Test Rated to 284 °F |
Industry and OEM Specifications: Jacobs and Thompson Inc. certifies that the following product meets the required specifications; | UL900, Class 2 |